155 research outputs found

    Co-axial dual-core resonant leaky fibre for optical amplifiers

    Get PDF
    We present a co-axial dual-core resonant leaky optical fibre design, in which the outer core is made highly leaky. A suitable choice of parameters can enable us to resonantly couple power from the inner core to the outer core. In a large-core fibre, such a resonant coupling can considerably increase the differential leakage loss between the fundamental and the higher order modes and can result in effective single-mode operation. In a small-core single-mode fibre, such a coupling can lead to sharp increase in the wavelength dependent leakage loss near the resonant wavelength and can be utilized for the suppression of amplified spontaneous emission and thereby gain equalization of an optical amplifier. We study the propagation characteristics of the fibre using the transfer matrix method and present an example of each, the large-mode-area design for high power amplifiers and the wavelength tunable leakage loss design for inherent gain equalization of optical amplifiers.Comment: 6 page

    Dispersive properties of quasi-phase-matched optical parametric amplifiers

    Get PDF
    The dispersive properties of non-degenerate optical parametric amplification in quasi-phase-matched (QPM) nonlinear quadratic crystals with an arbitrary grating profile are theoretically investigated in the no-pump-depletion limit. The spectral group delay curve of the amplifier is shown to be univocally determined by its spectral power gain curve through a Hilbert transform. Such a constraint has important implications on the propagation of spectrally-narrow optical pulses through the amplifier. In particular, it is shown that anomalous transit times, corresponding to superluminal or even negative group velocities, are possible near local minima of the spectral gain curve. A possible experimental observation of such effects using a QPM Lithium-Niobate crystal is suggested.Comment: submitted for publicatio

    Quasiphasematched frequency doubling in a waveguide of a 1560 nm diode laser and locking to the rubidium D absorption lines

    Get PDF
    An external-cavity 1560-nm diode laser was frequency doubled in a 3-cm-long periodically poled LiNbO 3 waveguide doubler with 120% W 21 conversion efficiency. The 780-nm light was used to detect the D 2 transitions of Rb, and the laser frequency was locked to Doppler-broadened lines of Rb. Furthermore, the ϳ1 mW of second-harmonic power was sufficient for detecting the sub-Doppler lines of Rb, and the laser was locked to a 87 Rb crossover line. © 1996 Optical Society of America Lasers operating at f ixed and known frequencies near the 1550-nm transmission window of optical fibers are required for densely packed multiwavelength communication systems. 1 Such lasers may also be required for coherent optical communication systems to ease the acquisition and locking of a local oscillator laser to a transmitter laser and for achieving coldstart communication. 2 In addition, absolutely stabilized sources may be applicable to fiber-optic sensors and as frequency standards for high-resolution spectroscopy. Optical frequency standards can be realized by locking to atomic or molecular transitions. Molecular absorptions in the 1550-nm wavelength range, e.g., ammonia, 3 acetylene, 4,5 and hydrogen iodide, 6 are usually weak overtone or combination bands. Lasers at 1550 nm were locked to Doppler-broadened transitions of these molecules. 5 Atomic transitions that can be used as frequency references, e.g., transitions between excited states in noble gases (Ar, Kr, etc.) 2 and transitions between upper levels in Rb, 7 do not originate from the ground state. Hence additional excitation, electrical (with a discharge lamp 2 ) or optical (with another laser 7 ), is required for populating one of these upper levels. An alternative approach that may overcome the difficulties associated with frequency references near 1550 nm is second-harmonic generation (SHG) and locking to absorption lines near 780 nm. A thoroughly characterized reference at 780.25 nm is the atomicRb D 2 line. 8 This reference was already used to stabilize 1560-nm laser diodes with the internally generated second harmonic of diode lasers, 9 but the SHG power was only 2 pW. Recently bulk external SHG in KNbO 3 crystal with a second-harmonic power of 2.2 nW was employed for the same goal. 10 Locking to a Doppler-broadened line was possible, but the power level was not sufficient to saturate the absorption for locking to sub-Doppler lines. Frequency doubling in KNbO 3 was also used to lock to K at 770 nm, 11 with a second-harmonic power of 20 nW. Because the power levels of diode lasers near 1550 nm are quite low (typically a few milliwatts), higher-eff iciency frequency conversion is required for detection and locking to sub-Doppler lines as well as to improve the signal-to-noise ratio for locking to Dopplerbroadened lines. A technique that may achieve this goal is quasi-phase-matched 12 (QPM) frequency conversion in a waveguide. In QPM doubling, a periodic modulation of the material nonlinear coefficient compensates for the phase velocity mismatch between the fundamental and the second-harmonic waves. This technique permits the use of large nonlinear coefficients, e.g., d 33 , in LiNbO 3 that are not accessible by birefringent phase matching. In LiNbO 3 the improvement in conversion eff iciency compared with birefringent phase matching is ͑2d 33 ͞pd 31 ͒ 2 ϳ 20, where 2͞p is the QPM reduction factor and d 31 is the effective nonlinear coeff icient for birefringent phase matching. Further improvement in conversion efficiency is obtained by waveguide confinement. Furthermore, room-temperature operation, as well as relaxed temperature and wavelength tolerances, is possible. The use of QPM waveguides for optical frequency standards at the 1300-nm fiber-optic transmission window has already been demonstrated 13 : the second harmonic of a 1319-nm Nd:YAG laser was locked to I 2 transitions near 660 nm. We applied the technique of waveguide QPM frequency conversion for efficient single-pass doubling of a 1560-nm external-cavity diode laser. The second-harmonic power was sufficiently high that we could detect sub-Doppler lines, and the laser was locked to Doppler-broadened lines as well as to subDoppler lines of Rb near 780 nm. The experimental setup for locking to Doppler-broadened lines of Rb is shown i

    Broadly tunable mid- infrared femtosecond optical parametric oscillator using all-solid-state-pumped periodically poled lithium niobate

    Get PDF
    We describe a high-repetition-rate femtosecond optical parametric oscillator (OPO) that was broadly tunable in the mid infrared. The all-solid-state-pumped OPO was based on quasi-phase matching in periodically poled lithium niobate. The idler was tunable from approximately 1.7 mm to beyond 5.4 mm, with maximum average power levels greater than 200 mW and more than 20 mW of average power at 5.4 mm. We used interferometric autocorrelation to characterize the mid-infrared idler pulses, which typically had durations of 125 fs. This OPO had a pumping threshold as low as 65 mW of average pump power, a maximum conversion efficiency of .35% into the near-infrared signal, a slope efficiency for the signal of approximately 60%, and a maximum pump depletion of more than 85%. © 1997 Optical Society of America Mid-IR femtosecond pulses have potential applications for the study of dynamics in a variety of materials. Vibrational relaxations in molecules, intersubband transitions in quantum wells, and materials for use in lasers and detectors operating in the 3-5-mm atmospheric transmission window can all be studied effectively with ultrashort mid-IR pulses. In this Letter we report on the generation of mid-IR pulses with an all-solid-state-pumped high-repetition-rate femtosecond (fs) optical parametric oscillator (OPO). The most-common techniques for the generation of high-repetition-rate mid-IR fs pulses are differencefrequency mixing and the use of a synchronously pumped OPO. Difference frequency of the signal and the idler output from Ti:sapphire-pumped OPO's produced fs pulses of between 2.5 and 5.5 mm (Ref. 1) but with maximum average power levels of only 500 mW . Mid-IR synchronously pumped fs OPO's based on KTiOPO 4 and its isomorphs 2 -5 were demonstrated, but they were limited to wavelengths shorter than ϳ4.1 mm. Average power levels greater than 20 mW at 5.2 mm were obtained with KNbO 3 . 6 The all-solid-state-pumped broadly tunable mid-IR fs OPO described in this Letter is based on quasi-phase matching 7 (QPM) in periodically poled lithium niobate (PPLN) and produced more than 20 mW of average power at 5.4 mm. The experimental arrangement was similar to that described in Ref. 8, except that a ring cavity was used instead of a linear cavity. We used a pumping geometry with a small noncollinear angle between the pump and the signal so that the long-wavelength idler beam did not have to be transmitted through any of the cavity optics and optical isolation of the pump laser was unnecessary. The PPLN OPO was synchronously pumped at a repetition rate of 81 MHz by a mode-locked fs Ti:sapphire laser powered by a diodepumped cw frequency-doubled Nd : YVO 4 laser (SpectraPhysics Millennia). The Ti:sapphire laser produced nearly transform-limited pulses of ϳ 90-fs duration, with average power levels of as much as 850 mW over the 790-815-nm wavelength range used in this experiment. We used two optics sets and two PPLN crystals, which were antiref lection coated on both sides with single layers of SiO 2 , in the OPO to cover the tuning range. In both cases the signal was resonated in a ring cavity consisting of two 15-cm radius-of-curvature mirrors, a f lat high ref lector, a f lat output coupler, and a four-prism (SF-14) sequence for dispersion compensation. Several different output couplers were used, with transmission varying from ϳ1% to ϳ9% over the tuning range of the OPO. In a noncollinear fs OPO both temporal walk-off owing to the group-velocity mismatch (GVM) of the interacting pulses and spatial walk-off owing to the noncollinearity of the interacting beams can limit the effective interaction length in the crystal. Near degeneracy 9 the GVM between the pump pulses and signal and idler pulses was of the order of 300 fs͞mm (signal-and-idler-leading pump), 10 resulting in a temporal walk-off length 11 of the order of 330 mm for ϳ100-fs pulse widths. Far from degeneracy, the GVM between pump and signal was reduced to as little as ϳ110 fs͞mm, but the GVM between signal and idler became as large as ϳ260 fs͞mm (signal-leading idler), resulting in a temporal walk-off length of ϳ900 mm between the pump and the signal and ϳ 380 mm between the signal and the idler. For the focusing parameters (ϳ35-mm signal and pump waist radius) and the noncollinear angle (varied from ϳ1.0 ± to ϳ1.6 ± between pump and signal measured internal to the crystal) used in this experiment, near degeneracy the spatial walk-off length of ϳ 550 mm between signal and idler was much larger than the temporal walk-off length and, therefore, did not limit the interaction length. When we were trying to reach long idler wavelengths, however, the increasingly large angle between signal and idler (as large as 9 ± measure

    Extradural autologous temporal muscle graft mimicking a meningioma: Case report

    Get PDF
    Meningiomas are the most common dural tumour, but there are also many other dural masses which mimic their appearances, such as neoplastic and non-neoplastic lesions. In this paper we report another mass which may mimic a dural lesion, namely a muscle graft harvested from the temporal site and left in situ, used to achieve haemostasis in a posttraumatic temporal extradural hematoma in a young male patient. Solid knowledge of differentiating neuroimaging characteristics of dural masses, as well as its corroboration with the patient’s medical history are extremely helpful in establishing an accurate diagnostic

    Orbitocranial penetrating injury by a metallic foreign body: Case report and anatomical considerations

    Get PDF
    Orbitocranial penetrating injuries (OPI) represent a rare type of head injuries encountered in clinical practice. These appear after falls or motor vehicle accidents and are more frequent among children. We present the case of a male patient with OPI, associated with large frontal hemorrhagic contusion, with minimal periorbital trauma findings related to brain injury. Knowing and understanding the clinical anatomy of the orbit and the patterns of injuries in OPI are mandatory, since failure in detecting intracranial complications may lead to the increase of the neurological morbidity, visual loss and death

    Wave-front engineering by Huygens-Fresnel principle for nonlinear optical interactions in domain engineered structures

    Full text link
    The wave-front engineering for nonlinear optical interactions was discussed. Using Huygens-Fresnel principle we developed a general theory and technique for domain engineering with conventional quasi-phase-matching structures being the special cases. By Fourier analysis we put forward the concept of local quasi-phase matching, which suggests that the quasi-phase matching is fulfilled only locally not globally. Experiments on focal effect of second-harmonic wave agreed well with the theoretical prediction. The proposed scheme combines three optical functions: generation, focusing and beam splitting of second-harmonic wave, thus making the device more compact. Further the proposed scheme can be used to perform the integration of multi-functional optical properties in nonlinear photonics, as well as expand the use of nonlinear optical devices.Comment: 15 pages, 3 figure

    Entangled-Photon Generation from Parametric Down-Conversion in Media with Inhomogeneous Nonlinearity

    Full text link
    We develop and experimentally verify a theory of Type-II spontaneous parametric down-conversion (SPDC) in media with inhomogeneous distributions of second-order nonlinearity. As a special case, we explore interference effects from SPDC generated in a cascade of two bulk crystals separated by an air gap. The polarization quantum-interference pattern is found to vary strongly with the spacing between the two crystals. This is found to be a cooperative effect due to two mechanisms: the chromatic dispersion of the medium separating the crystals and spatiotemporal effects which arise from the inclusion of transverse wave vectors. These effects provide two concomitant avenues for controlling the quantum state generated in SPDC. We expect these results to be of interest for the development of quantum technologies and the generation of SPDC in periodically varying nonlinear materials.Comment: submitted to Physical Review

    Intrinsic NLRP3 inflammasome activity is critical for normal adaptive immunity via regulation of IFN-γ in CD4+ T cells

    Get PDF
    The NLRP3 inflammasome controls interleukin-1b maturation in antigen-presenting cells, but a direct role for NLRP3 in human adaptive immune cells has not been described.We found that the NLRP3 inflammasome assembles in human CD4+ Tcells and initiates caspase-1–dependent interleukin-1b secretion, thereby promoting interferon-g production and T helper 1 (TH1) differentiation in an autocrine fashion. NLRP3 assembly requires intracellular C5 activation and stimulation of C5a receptor 1 (C5aR1), which is negatively regulated by surface-expressed C5aR2. Aberrant NLRP3 activity in Tcells affects inflammatory responses in human autoinflammatory disease and in mouse models of inflammation and infection. Our results demonstrate that NLRP3 inflammasome activity is not confined to “innate immune cells” but is an integral component of normal adaptive TH1 responses

    Anatomical localization of intracranial grade II meningiomas in North-Eastern Romania: Our 25-years experience

    Get PDF
    Objective. Our research aims to assess a possible connection between tumour localization and histological subtypes of grade II meningiomas. Material and methods. 143 patients with grade II WHO meningiomas underwent surgical resection in "Prof. Dr. N. Oblu" Emergency Clinical Hospital Ia?i between 1990 and 2015. The collected data included: patient age, gender, tumour localization and histopathological diagnosis (atypical, clear cells and chordoid meningioma). Results. 135 (94.4%) of all 143 patients with grade II meningiomas were atypical meningiomas, 6 (4.2%) were cell clear meningiomas and only 2 (1.4%) were chordoid meningiomas. As concerns their distribution by gender, 79 (55.2%) were female and 64 (44.8%) were male. Grade II meningiomas were most commonly located at convexity 49.7% (n=71), followed by skull base in 30.8% (n=44) of the cases and parasagittal/falcine in 14.7% (n=21) of the patients. Conclusions. The most common localization of grade II meningiomas was convexity, followed by skull base, parasagittal/falcine and intraventricular areas. We have also noticed that convexity meningiomas are more frequent in women, unlike the other anatomical localizations in which the male-female ratio is almost equal. Therefore, further research is necessary to determine the role of embryological, anatomopathological and genetic factors in underlying the connection between meningioma grade and anatomical localization
    corecore